A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AWT GLOBAL T5280A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   AWT GLOBAL T5280A   Description / Specification:    
AWT GLOBAL T5280A 8.0 GHz, 2 port Vector Network Analyzer

The AWT-Global T5280A is a high performance VNA that has large dynamic range, low noise level and low trace noise. Its frequencies cover all bands of wireless communication. This VNA is widely used in microwave device measurement in wireless communication, broadcast, television devices, radar devices, semi conductors and many more.

Specifications.

Measurement Range.
Impedance: 50 Ω, 75 Ω (with adapter).
Test port connector: N-type (f).
Number of test ports: 2.
Frequency range: 300 kHz to 8.0 GHz.
Full CW frequency accuracy: +/- 5 x 10-6
Frequency resolution: 1 Hz.
Measurement points: 2 to 10001.
Measurement bandwidths: 1 Hz to 30 kHz (in 1/ 1.5/ 2/ 3/ 5/ 7 steps).
Dynamic range: 130 dB/135 dB typ. (IFBW=10Hz).

Measurement Accuracy.
Accuracy of transmission measurements (magnitude/phase):
  +5 to +15dB, 0.2 dB / 2°;
  -50 to +5 dB, 0.1 dB / 1°;
  -70 to - 50 dB, 0.2 dB / 2°;
  -90 to - 70 dB, 1.0 dB / 6°.
Accuracy of reflection measurements (magnitude/phase):
  -15 to 0 dB, 0.4 dB / 3°;
  -25 to -15 dB, 1.5 dB / 7°;
  -35 to -25 dB, 4.0 dB / 22°.
Trace noise magnitude: 1 mdB rms (IFBW = 3 kHz).
Temperature dependence: 0.02 dB.

Test Port Output.
Match (w/o system error correction): 18 dB.
Power range 300 kHz to 6.0 GHz: -55 dBm to +10 dBm (6.0 GHz to 8.0 GHz, -60 dBm to +5 dBm).
Power accuracy: +/- 1.5 dB.
Power resolution: 0.05 dB.
Harmonics distortion: < -25 dBc.
Non harmonics distortion: < -30 dBc.

Test Port Input.
Match (w/o system error correction): 18 dB.
Damage level: +26 dBm.
Maximum DC voltage: +35 V.
Noise level: < -120 dBm (IFBW = 10 Hz).

Measurement Speed.
Measurement time per point: 125 ms.
Source to receiver port switch overtime: <10 ms.



 

Standard Calibration $745.00 *
*This is a Web introductory price for one calibration of the AWT GLOBAL T5280A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your AWT GLOBAL T5280A CALIBRATION and/or AWT GLOBAL T5280A 8.0 GHz, 2 port Vector Network Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: